Checking Spray Gun Spitting and Paint Fisheyes

Separate irregular material delivery from contamination craters and prepare a useful diagnostic record for technical support.

Reviewed 21 November 2026

Investigate paint delivery problems and contamination defects separately. Describe whether the problem occurs in the spray pattern, appears in the wet film, or develops later. A short video of the pattern and a close photograph of the surface can help technical support distinguish the cases.

Record irregular delivery before dismantling

For spitting or pulsing, record whether it happens at trigger start, continuously or when the material level changes. Note the gun model, fluid setup, coating reference, supply arrangement and operating settings. Follow the exact gun manual for inspection, depressurization and cleaning before removing components.

Ask support to specify the inspection order and replacement parts for that model. Do not transfer another gun's tightening procedure or torque value to a TUBA configuration. After the specified service, repeat the trial under the recorded conditions before returning to the workpiece.

Investigate craters as a contamination problem

PPG describes fisheyes as craters appearing in wet paint and identifies substrate contamination, silicone, dirty air lines and contaminated handling materials among the causes. Its fisheye guidance covers cleaning, clean handling materials and air-system maintenance.

For a shared workshop, document nearby polishing products, lubricants and other possible contamination sources. Review the panel-cleaning process and the air supply with the coating supplier. Keep the next trial controlled so a change in preparation can be assessed independently of a gun adjustment.

Prepare a support request

Include clear photographs, the coating data sheet, the gun and air cap identifiers, the cleaning product used and a description of when the defect first appeared. State what changed since the last satisfactory result. These details make a remote assessment more useful than replacing parts without identifying the symptom.

Common questions

Does every crater mean the gun needs repair? No. Review surface preparation and contamination pathways as well as the equipment.

Can an additive replace the investigation? Use additives only within the selected coating system's instructions and supplier advice.

Send TUBA a diagnostic record for model-specific assistance.

More spray equipment guides